The gap has to refill before the light turns on

A layer print is usually described as an optical problem: project an image, cure it, lift, repeat. Between the lift and the next exposure there is a quiet hydrodynamic step. The part has moved away from the release film, leaving a gap equal to one layer thickness over the footprint of the cross-section. Resin must flow back into that gap, and the surface left by the flow must flatten, before the next image is projected. If either process is incomplete, the layer is short of material. The usual reaction is to add exposure. That cannot fix a gap that never filled.

A 20 mm by 20 mm solid cross-section printed at a 25 µm layer displaces 10 mm³ of resin per layer. A 40 mm tall version has about 1600 layers, so the machine moves roughly 16 mL of resin through a gap thinner than a human hair, hundreds of times per hour. At 10 µm the same part moves the same volume through a gap two and a half times smaller. Available refill time does not scale with demand.

Two physical processes set that time. Pressure-driven refill pushes resin into the gap as the part lifts; capillary levelling smooths the film left behind. Both become rapidly harder as the gap closes. The scaling is more useful than a memorised delay setting, which changes with geometry, temperature and lot.

Why layer height dominates the timing

For laminar flow into a slit of height h, width W and flow length L, the volumetric flow rate under a pressure difference Δp is approximately Q = W × h³ × Δp / (12 × η × L), where η is dynamic viscosity. The h³ term is the important part. Refill time per unit area is proportional to η × L / (h³ × Δp).

Capillary levelling gives the same dependence from a different direction. A surface ripple of wavelength λ on a film of thickness h decays with a time constant proportional to η × λ⁴ / (γ × h³), where γ is surface tension. Again viscosity is in the numerator and the cube of film thickness in the denominator. Halving the layer does not double the time needed to prepare it; it multiplies it by about eight, at the same temperature and pressure.

These are scaling relationships, not settings. Pressure, flow path and ripple wavelength depend on geometry and lift strategy; confirm the magnitude with coupons.

Layer heightGap relative to 50 µmRelative refill / levelling time
50 µm11
25 µm0.5about 8
10 µm0.2about 125

A process that survives a one-second wait at 50 µm has no reason to survive at 25 µm with the same wait. This is why thin layers cost cycle time, and why a machine can print a fine coupon at 25 µm but lose a large slab: the coupon offers a short flow path, the slab a long one.

Vat temperature is a viscosity control

Viscosity of a photopolymer falls steeply as temperature rises. Over the range a shop actually runs, roughly 18 to 30 degrees Celsius, viscosity approximately halves for every 8 to 12 degrees of increase. That is an order of magnitude for filled casting resins, not a constant. Measure your own resin at two temperatures; the warm-versus-cold ranking holds even when the factor differs.

Because refill time scales with viscosity, a cold vat needs a longer wait at the same geometry and layer height.

ConditionRelative viscosityRelative time needed
50 µm at 28 °C11
25 µm at 28 °C1about 8
25 µm at 18 °Cabout 2about 16
10 µm at 18 °Cabout 2about 250

The warm-afternoon calibration and the cold-morning failure are the same process at two viscosities. Room temperature is not vat temperature: the vat warms from the light engine and consecutive builds, and cools while idle. Log resin temperature at a fixed point in the vat once per build. That column turns a seasonal defect into a number you can act on.

Filled resins add shear history to the problem

Wax-filled and pigmented casting resins are suspensions, not simple liquids. Two consequences matter at thin layers. First, viscosity depends on shear rate and idle time; a rested resin can be stiffer at the low shear rates that dominate the final stages of refill. Second, the dispersed phase settles or forms loose aggregates during idle periods. When the largest aggregates approach the layer gap they bridge it or are strained out at narrow passages, producing local starvation that looks exactly like underexposure.

As an engineering rule of thumb, keep the largest aggregates well below the gap being printed; a D90 around one tenth of the layer height, about 2.5 µm at 25 µm, is a sensible target to verify rather than assume. Check the current lot's data and inspect resin that has sat unused. Stirring protocol matters as much as stirring: a defined cycle before the run, then a defined settling interval, so the resin starts each build in the same state.

A single viscosity reading at one spindle speed does not predict refill. Record low- and high-shear viscosity at a stated temperature and rest interval. Lots with similar low-shear readings but different recovery will print differently at 25 µm.

Protocol that separates refill from exposure

  1. Fix the exposure setting first. Run a dose ladder on a small-area coupon where refill is not limiting, then hold that dose fixed.
  2. Bring the vat to a recorded temperature and give it 30 to 60 minutes to equalise. Record the value at the same point in the vat every time.
  3. Prepare three coupons at the production layer height: a 20 mm by 20 mm solid square with an upward face, a group of 3 mm rods and 1 mm prongs, and a tall tower with a wide base and a flat plateau near the top. They span short, long and obstructed flow paths.
  4. Print the set at a rest-time ladder of 0, 1, 2 and 4 seconds, changing nothing else. Keep lift distance and lift speed fixed so refill is the only variable.
  5. Score each upward face as missing-area fraction from a backlit photo at fixed exposure and distance. Ignore side walls and support marks.
  6. Repeat the ladder at a second vat temperature at least 8 degrees away from the first. A defect that moves with temperature is viscosity-driven; one that stays put is geometric.
  7. Measure viscosity at two shear rates for the lot used, and note the rest interval before measurement.
  8. If the solid square needs materially more rest than the rods, use an area-dependent rest setting rather than slowing every layer to the worst case.

A defect is refill-related when more rest alone reduces it. It is exposure-related when more dose alone reduces it, with rest held constant. If neither changes the result, look at mesh quality, focus, film condition or contamination before touching either parameter.

Failure modes and the test that settles each one

SymptomMost likely causeDiscriminating test
Pinholes on upward faces, random positionsBubbles entrained during refill; rest too shortAdd 2 s rest at fixed dose; pinholes that disappear were refill defects
Wavy thickness on large flat topsFilm still moving at exposureMeasure flatness of the 20 mm coupon at 0, 1, 2 and 4 s rest
Large solid areas short, fine features fineFlow path too long for the gapCompare the square and rod coupons at identical layer, dose and rest
Top of a tall part fails, base is soundObstructed refill over a tall part; lift distance insufficientPrint the tower rotated and change lift distance only
Failures on cold mornings, none in the afternoonViscosity rise at lower vat temperaturePlot missing-area fraction against logged vat temperature, not room temperature
First build after idle fails, later builds passFiller settling or thixotropic recoveryCompare identical coupons before and after a fixed 4 h idle with no stirring
Looks underexposed but dose ladder shows no windowRefill starvation mistaken for exposure errorRun the rest ladder at fixed dose; if voids shrink, stop tuning exposure
One region of the plate always worseUneven film tension or local flow obstructionPrint the same coupon at five plate positions and map the result

Each row is decided by a single controlled change. Changing dose, rest, temperature and lift at the same time guarantees that the cause stays unknown, and the next lot will bring the defect back.

Rest time is not free

An extra three seconds per layer sounds trivial; on a 1600-layer build it is 80 minutes. Doubling rest globally to cure one geometry is expensive caution. Control vat temperature, shorten the flow path by changing orientation, give rest only to layers with a large cross-section, then add a small margin for lot variation.

Too much idle time also costs. In a filled resin, long periods without agitation let filler settle, so excessive waiting between layers can reproduce the starvation it was meant to prevent. Treat dwell time as having both a lower and an upper useful bound.

Control limits that hold in production

  • Log vat temperature, layer height, rest time and resin lot for every build. These four numbers explain most refill defects.
  • Set rest time by layer class rather than by job. A solid slab and a ring shank printed in the same run do not need the same preparation time.
  • Re-measure the rest ladder when the lot, the layer height or the temperature band changes. A setting inherited from another resin is not evidence.
  • Keep resin level and vat geometry constant. Flow length changes with depth, and a change in flow length changes refill time.
  • Do not use extra exposure to hide a refill defect. It cures the appearance on one lot and fails on the next.
  • Define a stirring and settling routine and follow it before every production run, including the first run after an idle period.

Bottom line

Recoating is a flow problem with an optical consequence. Refill and levelling time scale with viscosity and with the inverse cube of layer height, which is why halving the layer is far more demanding than a linear change suggests, and why a cold vat reproduces the failure of a thinner layer. Separate the two causes with a rest ladder at fixed dose and a dose ladder at fixed rest, run the comparison at two temperatures, and set waiting time by geometry instead of by habit. A pattern that never got its resin back will never be fixed by more light.